Flat RoofingContractors

Flat roof systems

Liquid-applied roofing in Hyde

Liquid membranes give Hyde property owners a jointless, cold-applied roof without laps or separate flashings. They are especially useful around pipes, rooflights and tight corners where sheet systems need lots of cutting. If the roof below is wet or rotten, we say so and quote for the right fix instead.

Grey liquid waterproofing and reinforcement fleece rolled around a vent pipe on a flat roofComputer-generated example image

Hyde at a glance

Postcode districts
SK14
Population
about 35,895 (GeoNames)
Council area
Tameside Council
Building approval
Tameside Council building control, or a registered building control approver
Nearest main town
Stockport, about 4 miles
Guide price region
North West (−5% on West Midlands rates)

Why choose a liquid-applied roof in Hyde?

For businesses and landlords in Hyde, a cold-applied liquid roof means no flame on site and, with some systems, a short cure time. That can make it easier to work around occupied buildings, tenants and opening hours than a system that needs hot works or a long strip-out.

Around Hyde, flat roofs are common on 1930s semis with flat-roofed garages and kitchen extensions and on 1960s and 1970s link-detached houses with flat-roofed garages and porches. The North West is one of England's wetter regions, averaging roughly 1,290 mm of rain a year, so falls, outlets and well-detailed upstands matter more than the membrane colour.

How much does a liquid-applied roof cost in Hyde?

For Hyde we use North West rates: £1,950–£3,100 is the guide for a typical 18 m² garage roof in a liquid-applied system, VAT included. The fixed price comes after a free survey for new and replacement roofs.

JobGuide price inc VAT
Single garage (18 m²), liquid-applied£1,950–£3,100
Balcony (12 m²), liquid-applied, scaffold£1,800–£3,100
Single garage (18 m²), EPDM rubber£1,500–£2,650
Extension (20 m²), EPDM, new deck + insulation£2,650–£4,650

Do building regulations apply if a liquid coating goes over my roof?

They can. In England, Wales and Northern Ireland, re-covering more than half of a roof over a heated room is usually renovation of a thermal element, even when the new membrane goes over the old, so the roof should be insulated towards the renovation standard where feasible; for a Scottish property, the local building standards team will confirm whether a warrant is required.

A minor coating repair to a small area is different from re-covering the whole roof. Where insulation is needed, an overlay is not always practical, because the insulation has to go under a new waterproof layer. In that case we may recommend stripping to the deck, fitting a warm roof and applying the liquid system on top. Where approval applies, we deal with the paperwork; details are on the building regulations page.

What's included?

  • Detailing of upstands, outlets, pipes and corners before the main area
  • Surface cleaning, repairs and removal of loose material
  • Survey of the existing roof, including moisture and adhesion checks
  • Fleece-reinforced liquid membrane applied to the specified thickness

Building regulations in England

Replacing more than half of a flat roof over a heated room usually counts as renovating a thermal element, so the roof is insulated to around 0.16 W/m²K where that's technically and economically feasible, and the work is notified to building control: the council or a registered building control approver, unless a registered competent person self-certifies it. A roof on a new extension is built to 0.15 W/m²K. Patch repairs, and most unheated detached garages, don't trigger the upgrade. Structural changes, or a new covering that adds 15% or more to the roof's weight, also need approval. More on the rules.

Which nearby areas do we also cover?

Liquid-applied roofing in Hyde: questions

Do you cover Hyde?

Yes. Hyde is part of our Greater Manchester coverage, including postcode districts SK14. Surveys and roofs are carried out by vetted roofing teams working under S&K Property Investments and Improvement Ltd.

Who checks building regulations for a flat roof in Hyde?

Where the work needs approval it goes to Tameside Council building control, or a registered building control approver. We tell you at the survey whether your job needs it and deal with the paperwork as part of the quote.

How much does a liquid-applied roof cost in Hyde?

£1,950–£3,100 for a typical 18 m² garage roof in a liquid-applied system, at North West guide rates including VAT. The fixed price comes after a free survey for new and replacement roofs.

Is liquid roofing the same as a roof paint?

No. A proper liquid-applied membrane is built to a specified thickness and usually reinforced with fleece, while roof paints and simple coatings are much thinner and mainly used to extend the life of an existing covering.

What is a fleece-reinforced liquid roof?

It is a liquid membrane with a polyester fleece embedded between coats. The fleece adds strength, helps control thickness and resists cracking where the surface moves slightly.

Other flat roof work in Hyde

Liquid-applied roofing in Hyde: get a fixed price

Free survey and a written fixed quote for replacement and new roofs. No obligation.

Call usGet a guide price