Flat RoofingContractors

Flat roof systems

Torch-on felt roofing across Ceredigion

Torch-on felt roofing in Ceredigion follows the same process wherever the property sits: survey, written quote, strip, lay and sign-off. Rainfall and exposure vary across the area, so we specify membranes, laps and edge details to suit each roof and its site, and we never lay on a wet deck.

Roofer torching a slate-grey mineral cap sheet on a commercial flat roof behind edge protectionComputer-generated example image
Price per m²
£55–£97
Typical life
15–25 years
Manufacturer guarantees
10–20 year material guarantees on specified systems
Typical garage roof
£1,400–£2,400

Ceredigion at a glance

Largest towns
Aberystwyth
Postcode areas
SY
Building control
Ceredigion County Council
Neighbouring areas
Powys · Carmarthenshire · Neath Port Talbot · Swansea
Guide price region
Wales (−8% on West Midlands rates)

How much does a torch-on felt roof cost in Ceredigion?

Guide prices including VAT at Wales rates. The fixed price comes after a free survey for new and replacement roofs.

JobGuide price inc VAT
Single garage (18 m²), torch-on felt£1,400–£2,400
Extension (20 m²), felt, new deck + insulation£2,500–£4,300
Block of flats (150 m²), felt + insulation + scaffold£14,300–£25,000
Single garage (18 m²), EPDM rubber£1,450–£2,600
Extension (20 m²), EPDM, new deck + insulation£2,600–£4,500

Which flat roofs are common in Ceredigion?

Flat roofs in Ceredigion sit on 1960s and 1970s link-detached houses with flat-roofed garages and porches, lock-up garage blocks on estates and low-rise post-war blocks of flats. Wales averages roughly 1,460 mm of rain a year, among the wettest in Britain, so we design for steady run-off: proper falls, clear outlets and upstands well above the finished roof. Approximate 1991–2020 regional averages based on Met Office data.

Building regulations in Wales

Welsh guidance is that most re-roofing needs building control approval, so it's worth checking whenever more than a quarter of a roof is replaced or repaired. Renovated roofs are upgraded to around 0.16 W/m²K where feasible, and new extension roofs are built to 0.13 W/m²K under the Welsh Approved Document L. In Ceredigion the application goes to Ceredigion County Council. More on the rules.

Is torch-on roofing safe, and what is the difference between two- and three-layer systems?

Yes, torch-on is safe when hot works are properly controlled, because most roof fires linked to torching start at hidden timber or debris near edges and upstands, not on the open roof. Our teams follow a hot-works routine on every job:

  • check eaves, fascias, soffits and wall cavities for timber, nests and debris before lighting a torch;
  • use a cold-applied or self-adhesive membrane, rather than a flame, at edges, against combustible materials and in tight details;
  • keep fire extinguishers on the roof and the gas bottles secured and away from the work;
  • stop torching well before the team leaves, then carry out a fire watch so smouldering is spotted while people are still on site.

As for layers, a two-layer system (underlay plus cap sheet) is common on domestic roofs such as garages and extensions. A three-layer system adds an intermediate sheet, giving more thickness and redundancy, and is often specified on larger, commercial and multi-occupied roofs. The right choice depends on the size and use of the roof and the system's requirements, so we set it out in the quote.

Near a boundary, the external fire performance of the tested build-up, such as a BROOF(t4) classification, can also matter, and we check it where it applies.

Does replacing a felt roof mean upgrading the insulation?

Usually, yes, when the roof is over a heated space and more than half of it is being re-covered. In England, Wales and Northern Ireland that is renovation of a thermal element, which should be brought towards the renovation U-value where feasible; a Scottish project goes through the council's building standards service, which confirms whether a warrant applies.

A felt replacement is a good point to switch to a warm roof, with insulation laid above the deck under the new membranes. On larger roofs, tapered insulation can also correct poor falls that have caused ponding, which a patch repair cannot fix. Raising the roof level affects upstands and door thresholds, so we check heights at survey. Any approval is arranged by us as part of the job, and the building regulations page sets out the rules by nation.

Which towns in Ceredigion do we cover?

Torch-on felt roofing in Ceredigion: questions

Which towns in Ceredigion do you cover?

All of Ceredigion. The main towns have their own pages below, and if yours isn't listed we still cover it: send your postcode and we'll confirm.

How much does a torch-on felt roof cost in Ceredigion?

£1,400–£2,400 for a typical 18 m² garage roof in torch-on felt, at Wales guide rates including VAT. The fixed price comes after a free survey for new and replacement roofs.

Which postcode areas do you cover in Ceredigion?

All of Ceredigion, including the SY postcode areas. Send your full postcode and we'll confirm.

Why does my felt roof have blisters?

Blisters usually form when moisture or air trapped beneath the felt expands in the sun. A few small, intact blisters may be monitored, but widespread or split blisters point to a repair or replacement.

Is torch-on suitable for a block of flats?

Yes, layered bitumen systems are widely used on blocks of flats and commercial buildings. Larger roofs often use three layers and insulation, with hot works planned around residents.

Is torch-on felt better than the old felt roofs?

Yes, considerably. Modern torch-on membranes are polymer-modified and polyester-reinforced, laid in bonded layers, and typically last much longer than the older felt systems they replace.

Everything about torch-on felt roofing → · All flat roofing in Ceredigion →

Get a fixed price for your flat roof

Free survey and a written fixed quote for replacement and new roofs. No obligation.

Call usGet a guide price