Torch-on felt roofing in Irvine

Replacing an old felt roof in Irvine? Modern torch-on systems are far tougher than the felt many people remember. We strip the existing covering, repair the deck, add warm-roof insulation where needed and lay new membranes with staggered laps. Guide prices are online, and the fixed price comes after our free survey.

Roofer torching a slate-grey mineral cap sheet on a commercial flat roof behind edge protectionComputer-generated example image

Irvine at a glance

Postcode districts
KA11, KA12
Population
about 34,130 (GeoNames)
Council area
North Ayrshire Council
Building approval
North Ayrshire Council building standards
Nearest main town
Kilmarnock, about 6 miles
Guide price region
Scotland (−5% on West Midlands rates)

Why choose torch-on felt roofing in Irvine?

Where a flat roof in Irvine already has a felt covering and the building owner wants like-for-like, torch-on is the natural replacement. The old roof is stripped, the deck checked and the new layers laid, often with warm-roof insulation added when the space below is heated.

In and around Irvine, flat roofs are typically found on lock-up garage blocks on estates, and on bungalows with flat-roofed side extensions and dormers. Scotland averages roughly 1,570 mm of rain a year, with the west far wetter than the east, so drainage, falls and wind uplift are part of every specification we write.

How much does a torch-on felt roof cost in Irvine?

For Irvine we use Scotland rates: £1,450–£2,500 is the guide for a typical 18 m² garage roof in torch-on felt, VAT included. The fixed price comes after a free survey for new and replacement roofs.

JobGuide price inc VAT
Single garage (18 m²), torch-on felt£1,450–£2,500
Extension (20 m²), felt, new deck + insulation£2,550–£4,450
Block of flats (150 m²), felt + insulation + scaffold£14,750–£25,850
Single garage (18 m²), EPDM rubber£1,500–£2,650
Extension (20 m²), EPDM, new deck + insulation£2,650–£4,650

Is torch-on roofing safe, and what is the difference between two- and three-layer systems?

Yes, torch-on is safe when hot works are properly controlled, because most roof fires linked to torching start at hidden timber or debris near edges and upstands, not on the open roof. Our teams follow a hot-works routine on every job:

  • check eaves, fascias, soffits and wall cavities for timber, nests and debris before lighting a torch;
  • use a cold-applied or self-adhesive membrane, rather than a flame, at edges, against combustible materials and in tight details;
  • keep fire extinguishers on the roof and the gas bottles secured and away from the work;
  • stop torching well before the team leaves, then carry out a fire watch so smouldering is spotted while people are still on site.

As for layers, a two-layer system (underlay plus cap sheet) is common on domestic roofs such as garages and extensions. A three-layer system adds an intermediate sheet, giving more thickness and redundancy, and is often specified on larger, commercial and multi-occupied roofs. The right choice depends on the size and use of the roof and the system's requirements, so we set it out in the quote.

Near a boundary, the external fire performance of the tested build-up, such as a BROOF(t4) classification, can also matter, and we check it where it applies.

What's included?

  • Mineral-finished cap sheet, upstands, outlets and edge trims
  • Two- or three-layer reinforced bitumen membrane with staggered laps
  • Hot-works checks and fire watch on every torch-on job
  • Deck inspection with replacement of damaged boards

Building standards in Scotland

In Scotland the building standards technical handbooks (Section 6 for energy) apply, and the council's building standards service decides whether a building warrant is needed. Like-for-like repairs to a roof covering can be exempt; alterations, structural work and new roofs usually need a warrant before work starts. The domestic roof benchmark is 0.12 W/m²K, applied as far as reasonably practicable on an existing roof. More on the rules.

Which nearby areas do we also cover?

Torch-on felt roofing in Irvine: questions

Do you cover Irvine?

Yes. Irvine is part of our North Ayrshire coverage, including postcode districts KA11, KA12. Surveys and roofs are carried out by vetted roofing teams working under S&K Property Investments and Improvement Ltd.

Who checks building standards for a flat roof in Irvine?

Where the work needs approval it goes to North Ayrshire Council building standards. We tell you at the survey whether your job needs it and deal with the paperwork as part of the quote.

How much does a torch-on felt roof cost in Irvine?

£1,450–£2,500 for a typical 18 m² garage roof in torch-on felt, at Scotland guide rates including VAT. The fixed price comes after a free survey for new and replacement roofs.

Can torch-on felt go over an existing felt roof?

Sometimes, if the old roof is dry, well bonded and the deck is sound. Often stripping is better, because overlaying can trap moisture and hide rot; our guide to overlay or strip explains how we decide.

Can torch-on felt be laid in wet weather?

Not in rain or on a wet deck, because moisture trapped under the membrane causes blisters. Light cold weather is usually workable, but we will postpone rather than lay on a damp surface.