- Price per m²
- £53–£92
- Typical life
- 15–25 years
- Manufacturer guarantees
- 10–20 year material guarantees on specified systems
- Typical garage roof
- £1,350–£2,300
County Down at a glance
- Largest towns
- Bangor, Newtownards, Newry, Banbridge
- Postcode areas
- BT
- Building control
- Ards and North Down Borough Council, Newry, Mourne and Down District Council, Armagh City, Banbridge and Craigavon Borough Council and 1 other council
- Neighbouring areas
- Belfast · County Antrim · County Armagh · County Tyrone
- Guide price region
- Northern Ireland (−12% on West Midlands rates)
How much does a torch-on felt roof cost in County Down?
Guide prices including VAT at Northern Ireland rates. The fixed price comes after a free survey for new and replacement roofs.
| Job | Guide price inc VAT |
|---|---|
| Single garage (18 m²), torch-on felt | £1,350–£2,300 |
| Extension (20 m²), felt, new deck + insulation | £2,400–£4,100 |
| Block of flats (150 m²), felt + insulation + scaffold | £13,700–£23,950 |
| Single garage (18 m²), EPDM rubber | £1,400–£2,450 |
| Extension (20 m²), EPDM, new deck + insulation | £2,450–£4,300 |
Which flat roofs are common in County Down?
Flat roofs in County Down sit on terraced streets with flat-roofed rear kitchens and bathrooms, 1930s semis with flat-roofed garages and kitchen extensions and low-rise post-war blocks of flats. Northern Ireland averages roughly 1,150 mm of rain a year, spread over many wet days, so a roof that sheds water quickly to clear outlets lasts far longer than one that holds puddles. Approximate 1991–2020 regional averages based on Met Office data.
Building control in Northern Ireland
In Northern Ireland, renovating or replacing a roof over a heated room usually means meeting Technical Booklet F1, and building control should be contacted before work starts. Technical Booklet F1 sets roof insulation at 0.18 W/m²K when a roof over a heated room is renovated or newly built, where feasible. In County Down the application goes to Ards and North Down Borough Council, Newry, Mourne and Down District Council, Armagh City, Banbridge and Craigavon Borough Council and 1 other council. More on the rules.
Is torch-on roofing safe, and what is the difference between two- and three-layer systems?
Yes, torch-on is safe when hot works are properly controlled, because most roof fires linked to torching start at hidden timber or debris near edges and upstands, not on the open roof. Our teams follow a hot-works routine on every job:
- check eaves, fascias, soffits and wall cavities for timber, nests and debris before lighting a torch;
- use a cold-applied or self-adhesive membrane, rather than a flame, at edges, against combustible materials and in tight details;
- keep fire extinguishers on the roof and the gas bottles secured and away from the work;
- stop torching well before the team leaves, then carry out a fire watch so smouldering is spotted while people are still on site.
As for layers, a two-layer system (underlay plus cap sheet) is common on domestic roofs such as garages and extensions. A three-layer system adds an intermediate sheet, giving more thickness and redundancy, and is often specified on larger, commercial and multi-occupied roofs. The right choice depends on the size and use of the roof and the system's requirements, so we set it out in the quote.
Near a boundary, the external fire performance of the tested build-up, such as a BROOF(t4) classification, can also matter, and we check it where it applies.
Should I choose torch-on felt or a different flat roof system?
Choose torch-on felt when you want a proven, layered system at a sensible price, particularly on larger roofs, blocks of flats and commercial buildings where several layers give useful redundancy. It is a weaker choice where hot works are hard to manage safely.
For: generally lower cost per square metre; two or three layers, so a single defect in one layer need not cause a leak; tough mineral finish; long track record and a British Standard code of practice; repairs can be made with compatible materials.
Against: needs a naked flame unless a cold-applied or self-adhesive alternative is used; shorter typical life than EPDM or GRP; the finish is functional rather than decorative; more laps to detail than a single sheet.
On small domestic roofs near timber, EPDM avoids the torch entirely. GRP gives a harder, neater surface. For an overlay, a liquid-applied system is often simpler. Large commercial roofs may suit single-ply, and older buildings may suit mastic asphalt. See our comparison guide.
Which towns in County Down do we cover?
- Bangor
- Newtownards
- Newry
- Banbridge
- Dundonald
- Holywood
- Downpatrick
- Comber
- Carryduff
- Warrenpoint
- Newcastle
- Donaghadee
Torch-on felt roofing in County Down: questions
Which towns in County Down do you cover?
All of County Down. The main towns have their own pages below, and if yours isn't listed we still cover it: send your postcode and we'll confirm.
How much does a torch-on felt roof cost in County Down?
£1,350–£2,300 for a typical 18 m² garage roof in torch-on felt, at Northern Ireland guide rates including VAT. The fixed price comes after a free survey for new and replacement roofs.
Which council handles building control for a flat roof in County Down?
It depends on where the roof is: in County Down that's Ards and North Down Borough Council, Newry, Mourne and Down District Council, Armagh City, Banbridge and Craigavon Borough Council and 1 other council. In Northern Ireland, renovating or replacing a roof over a heated room usually means meeting Technical Booklet F1, and building control should be contacted before work starts. We confirm which applies at the survey.
Why does my felt roof have blisters?
Blisters usually form when moisture or air trapped beneath the felt expands in the sun. A few small, intact blisters may be monitored, but widespread or split blisters point to a repair or replacement.
Is torch-on suitable for a block of flats?
Yes, layered bitumen systems are widely used on blocks of flats and commercial buildings. Larger roofs often use three layers and insulation, with hot works planned around residents.
Can torch-on felt be laid in wet weather?
Not in rain or on a wet deck, because moisture trapped under the membrane causes blisters. Light cold weather is usually workable, but we will postpone rather than lay on a damp surface.
Everything about torch-on felt roofing → · All flat roofing in County Down →